System
Power Demand: Approximately 500 VA
Supply Voltage: 230/460 V + 10% 60 HZ Power Panel
220/440 V + 10% 50 HZ Power Panel
(Other voltages available upon request)
Temperature range: 0 to 50 degrees C
Speed: 1 to 5000 ft/min
Sensitivity: 0.001 In. diameter hole
Strip Thickness:
Suggested Upper Limit: 0.065 In.
Limited by Shutter: 0.185 In.
Dimensions and Weights
Model Scanner Size Weight 4800 23 In. X 10 In. X 84 In. 550lbs 5400 23 In. X 10 In. X 84 In. 570 lbs 6000 24 In. X 10 In. X 102 In. 590 lbs 7200 24 In. X 10 In. X 116 In. 650 lbs 8400 24 In. X 10 In. X 130 In. 700 lbs 9600 24 In. X 10 In. X 144 In. 750 lbs
Strip Width
Maximum by
Model*; 4800 5400 6000 7200 8400 9600 Auto Shutters Threaded 47 In. 52 In. 67 In. 74 In. " " Inspect 45 In. 46 In. 60 In. 72 In. Custom Configurations Manual Shutters Threaded 54 In. 54 In. 68 In. 80 In. " " Inspect 48 In. 48 In. 62 In. 76 In. " " Minimum which can
be inspected 12 In.
centered Strip Weave Any within
width limits.
*Approximate Dimensions - Other sizes are available on special request |
Shutter Overlap: 0.0625 In. minimum at all times. This is normally set to 0.125 In.
Shutter Deadband: +/- .04 In. to +/- .1 In. (factory set approx. .06 In.)
Shutter Speed: 240 or 375 In. per minute for 60 HZ Power Frequency
200 or 312 In. per minute for 50 HZ Power Frequency
(Factory set to lower speed. Field changeable as required.)
Strip weave speed MUST be less than shutter speed
Typical speed-overlap relationships:
Shutter speed: 240 In. per minute to 375 In. per Min
Normal Overlap: .125 In. to .185 In.
Minimum Deadband: +/- .05 +/- .08 In.
Outputs
Relay Contact: DPDT 2 amp at 115 VAC resistive protection required for other loads.
Derate for incandescent lamp loads with high in-rush (1/10 rating).
Closure Delay: Approximately 10 milliseconds after detection.
Closure Duration: Adjustable, approximately 10 to 60 Milliseconds.
Single Pulse: No holes = 0.0V to -0.6V
Pinhole = +9V
Output Impedance: Approximately 100 OHMS
Minimum load Impedance: Approximately 10K OHMS
Pulse Duration Approximately 0.8 Milliseconds
Pulse frequency Approximately 500 HZ
Duration of Output Equal to time Pinhole is in inspection zone.
Interlock - supplied by customer
Function: Line Start
Type: Open when Line Stopped
Closes when Line starts
Shutter Retract Switch (to be supplied by Customer) – (Auto shutters only)
Type SPST – Shutters retract to limit when closed
Options
Automatic Shutters
Defect Marker System
Weld Hole Detectors
Wide or Narrow Widths
Classifier Systems
Coil Reporting
Multi-Channel or Zone
detection